Features
![]() | Sentinel™ Gold Microprocessor Control system
|
![]() | Dual DC-ECM Blower System
|
![]() | ULPA Filter
|
![]() | Cabinet construction
|
![]() | Ergonomic features
|
![]() | Isocide™ Antimicrobial Powder Coating
|
Improving Lives Through Science
Class II Biological Safety Cabinet
› Products › Biological Safety Cabinet › Class II BSC › Airstream® Gen 3 Class II BSC- D Series
The Esco Airstream® Class II Biological Safety Cabinet (AC2) is an effective solution in providing operator, product and environmental protection. It also features stable and self-compensating airflow, despite building voltage fluctuations & filter loading. Compliant to EN 12469, Esco Airstream® Class II Biological Safety Cabinet also has antimicrobial coating on all its external and internal painted surfaces for improved safety.
The AC2-D series is equipped with Dual blowers for inflow and downflow which is a redundant system that provides protection in case of fan failure.
![]() | Sentinel™ Gold Microprocessor Control system
|
![]() | Dual DC-ECM Blower System
|
![]() | ULPA Filter
|
![]() | Cabinet construction
|
![]() | Ergonomic features
|
![]() | Isocide™ Antimicrobial Powder Coating
|
| Item Code | Model Code | Description |
|---|---|---|
| 220-240 VAC, 50/60 Hz | ||
| 2010733 | AC2-4D8 | Airstream® Class II, Biological Safety Cabinet (D-Series), 4ft/1.2m |
| 2010742 | AC2-6D8 | Airstream® Class II, Biological Safety Cabinet (D-Series), 6ft/1.8m |
| Item Code | Model Code | Description |
|---|---|---|
| 5170255 | UV-30A | UV Lamp for 4ft, 5ft, 6ft Cabinets except AC3-4B |
| Service Fixtures | ||
| 5170410 | SF-1G20 | European Style Service Fixture with 20mm Thread Length - Gas |
| 5170457 | SF-1V20 | European Style Service Fixture with 20mm Thread Length - Vacuum |
| 5170503 | SF-1N20 | European Style Service Fixture with 20mm Thread Length - Nitrogen |
| 5170502 | SF-1A20 | European Style Service Fixture with 20mm Thread Length - Air |
| 5170458 | SF-1W20 | European Style Service Fixture with 20mm Thread Length - Water |
| 5170504 | SF-2U22 | American Style Service Fixture with 22mm Thread Length - Universal |
| 5170026 | CU-Pipe | Copper Piping for Service Fixture - Must be Factory Installed |
| Support Stands | ||
| SPC-_A0 Gen2 | Support Stand with Caster Wheels (Height 28”) | |
| SPC-_B0 Gen 2 | Support Stand with Caster Wheels (Height 34”) | |
| SAL-_A0 Gen 2 | Support Stand with Leveling Feet - I (Height 28”) | |
| SAL-_B0 Gen 2 | Support Stand with Leveling Feet - I (Height 34”) | |
| IV Bars | ||
| 5170498 | IV-605 | IV Bar 605mm |
| 5170499 | IV-910 | IV Bar 910mm |
| 5170231 | IV-1215 | IV Bar 1215mm |
| 5170500 | IV-1520 | IV Bar 1520mm |
| 5170501 | IV-1825 | IV Bar 1825mm |
| Pre-Filters | ||
| 5090062 | PF-42 | Prefilter, 1200x125x6mm, AC2-4ft |
| 5090064 | PF-44 | Prefilter, 1810x125x6mm, AC2-6ft |
Airstream® G3 Class II BSC Italian Brochure
Airstream® G3 Class II BSC Serbian Brochure
Airstream® G3 Class II BSC French Brochure
Airstream® AC2 G3 Class II BSC German Brochure
Guide to Biosafety and Biological Safety Cabinets
Airstream® G3 Class II BSC Brochure
Esco Class II BSC Tri-fold brochure
Optimizing Safety: BSC Installation and Maintenance Best Practices
Repair or Replace Your Old Biosafety Cabinet?
BSC Maintenance Tips and Procedure
Safe Work Practices in a Biosafety Cabinet
Esco Hood Selection Guide
Ultraviolet Disinfection vs Human Coronaviruses
Formalin vs. Hydrogen Peroxide Decontamination