Application |
Classification and Feature
|
Protection Against |
Model |
Remarks |
A
Allergen
|
B
Biohazard
|
C
Chemical Vapor
|
D
Hazardous Drugs
|
E
Environmental Contaminants
|
A
Animal Handling Animal procedure,
anesthesia, cage transfer, bedding disposal, necropsy
Can accomodate trace amount of non-corrosive,
non-flammable chemicals with exhaust collar, heating
is NOT allowed
|
1 |
Single-Sided Animal Procedure, Class II A2 Biosafety |
✓
|
✓
|
Add Exhaust Collar |
Add Exhaust Collar |
✓
|
|
If using Isoflurane gas, add exhaust collar and gas scavenger unit.
Use SLC stand to move under 80" doors. Necropsy variant with sink is
available.
|
2 |
Double-Sided Animal Transfer |
✓
|
|
|
|
✓
|
|
Comes with auto-lift to slide under 80" doors at min height.
Quietest dual-sides animal cabinet in the market. ELISA- tested
allergen containment.
|
3 |
Bedding Disposal |
✓
|
|
|
|
✓
|
|
Comes with removable 40 gal waste disposal bin and auto-lift to
slide under 80" doors at min height. ELISA-tested allergen
containment.
|
B
Biological Samples Handling COVID-19, Gene
and Cell therapy, Mammalian cell culture, Cancer and Pharma
research
Can accomodate trace amount of non-corrosive,
non-flammable chemicals with exhaust collar, heating
is NOT allowed
|
1 |
Compact-sized, Class II A2 |
|
✓
|
Add Exhaust Collar |
Add Exhaust Collar |
✓
|
|
Energy and space efficient. Lowest BSC in market at 55" height. Add
exhaust collar when working with naturally evaporating chemicals.
|
2 |
Full-sized, Class II A2 |
|
✓
|
Add Exhaust Collar |
Add Exhaust Collar |
✓
|
|
Ultimate safety and comfort. Add exhaust collar when working with
naturally evaporating chemicals.
|
3 |
Machine enclosure, Class II A2 |
|
✓
|
Add Exhaust Collar |
Add Exhaust Collar |
✓
|
|
25" usable depth and 36" interior height. Add Exhaust Collar for
naturally evaporating chemicals. Use folding window for > 20"
larger front opening.
|
4 |
Room-Sized Enclosure, Class II A2 |
|
✓
|
Add Exhaust Collar |
Add Exhaust Collar |
✓
|
|
58" D x 34" D x 71" Workzone. Customizable to larger size. Add
exhaust collar when working with naturally evaporating chemicals.
|
5 |
Total Exhaust, for Continuous Chemical Injection, Class II B2 |
|
✓
|
✓
|
✓
|
✓
|
|
Has built-in Exhaust Collar. Also can be used for small amount of
non-corrosive flammable chemicals because vapor won't touch internal
fan.
|
C
Chemical Handling (Ducted) General
chemistry, Acid digestion chemistry, Radioisotope chemistry
Can accomodate wide-range of chemicals that
include corrosive and flammable chemicals, heating is allowed
|
1 |
General Purpose Fume Hood (Ducted) |
|
|
✓
|
|
|
|
Fiberglass-Reinforced Plastic Interior and Epoxy Resin Table.
Suitable for a wide range of chemicals at larger amount. Heating
allowed. C1D1 option.
|
2 |
Acid Digestion Fume Hood (Ducted) |
|
|
✓
|
|
|
|
Polypropylene Plastic Interior and Table. Suitable for a wide range
of chemicals at larger amount. Heating is allowed. C1D1 option.
|
3 |
Radioisotope Fume Hood (Ducted) |
|
|
✓
|
|
|
|
Stainless Steel 304 or 316 Interior and Table. Suitable for a wide
range of chemicals at larger amount. Heating is allowed. C1D1
option.
|
C
Chemical Handling (Ductless) General
chemistry, Portable chemical hood, Clean room chemical hood
For limited-range of chemicals per selected
carbon filter, heating is NOT allowed
|
1 |
Single-Layer Carbon Filter (Limited range of chemicals) |
|
|
✓
|
|
|
|
Choose 1 from 8 different types of carbon filter. Suitable only for
limited range of chemicals per selected carbon filter.
|
2 |
Double-Layer Carbon Filter (More range of chemicals) |
|
|
✓
|
|
|
|
Choose 2 from 8 different types of carbon filter. Suitable only for
limited range of chemicals per selected carbon filter.
|
3 |
Single-Layer Carbon + HEPA Filter (Chemical vapor and particulates)
|
|
|
✓
|
|
|
|
Choose 1 from 8 carbon filters. Limited range of chemicals per
selected filter. Suitable for clean room, as HEPA filter captures
the carbon particles
|
C
Compounding Pharmacy Chemo drugs
compounding, Epidural anesthetic injection
Can accomodate trace amount of non-corrosive,
non-flammable chemicals with exhaust collar, heating
is NOT allowed
|
1 |
Non-Hazardous, Sterile, USP-797 |
|
|
|
|
✓
|
|
LHG: Glass Sides, to put camera outside the cabinet
LHS: Stainless Steel Sides, easier to clean
Use STC stand with casters
|
2 |
Hazardous, Non-Sterile, USP 800 |
|
|
|
✓
|
|
|
PW1: single HEPA + collar
ADC-F: double HEPA
|
3 |
Hazardous, Sterile, USP 800 |
|
✓
|
Add Exhaust Collar |
Add Exhaust Collar |
✓
|
|
Add exhaust collar to comply with USP 800. Only for naturally
evaporating chemicals. Short 55" height for cleanrooms & mobile
labs.
|
D
DNA Amplification COVID-19, RNA reverse
transcript
Using PCR method
|
1 |
PCR Cabinet |
|
|
|
|
✓
|
|
Comes with UV lamp, foldable front cover, Blower, and HEPA Filter.
Has lower airflow at 60 fpm instead of 90 fpm for Laminar Flow
Cabinets.
|
E
Electronics Plant Tissue Culture Electronics
& Plant Tissue Culture Chip / PCB / Lens assembly, Plant
disease resistance research
Only provides product protection, no operator protection
|
1 |
Small Electronics, Plant Tissue Culture: use Horizontal Laminar Flow
Cabinet
|
|
|
|
|
✓
|
|
LHG: Glass Sides, to put camera outside the cabinet
LHS: Stainless Steel Sides, easier to clean, better for ESD
Add Ion Bar for ESD application
|
2 |
Larger Electronics, Agar Plate Preparation: use Vertical Laminar
Flow Cabinet
|
|
|
|
|
✓
|
|
LVG: Glass Sides, more comfortable from claustrophobia
LVS: Stainless Steel Sides, easier to clean, better for ESD
Add Ion Bar for ESD application
|
3 |
Optics Inspection: use Vertical Laminar Flow Cabinet with Black
Interior
|
|
|
|
|
✓
|
|
Black Interior Walls and Work Surface for Optical Instrument
Inspection
|